Confocal Microscopes – Ghent


Zeiss Spinning Disc

Name: Zeiss AxioObserver Spinning Disc (Yokogawa CSU-X1)
Application: 3D live cell imaging, whole mount imaging
Type: Invert confocal
Light Source: 405, 488, 561, 639 (diode lasers)
Objectives: EC Plan-Neofluar 10x/0.30 Ph 1
Plan- Apochromat 20x/0.80
LD LCI Plan-Apochromat 25x/0.8 Imm Korr DIC
Plan-Apochromat 40x/1.40 Oil DIC UV-Vis-IR
Plan-Apochromat 63x/1.40 Oil DIC
Detectors: AxioCam MRm
Photometrics Prime 95B
Filters: DAPI (BP 445/50)
HE GFP (FE01-520/35)
YFP (BP 535/30)
Texas Red (FE01-617/73)
Cy5 (BP 690/50)
DIC Analyzer for Transmitted Light
Room Location: W281

 


Zeiss LSM 710

Name: ZeissLSM710
Application: High resolution confocal imaging; two-photon excitation for deep tissue and whole organ imaging; spectral unmixing
Type: Upright confocal
Light Source: Diode lasers: 561, 633
Argon laser: 458, 488, 514
MaiTai DeepSee multiphoton laser: range 680 – 1040 nm
Objectives: Plan-Apochromat 5x/0.16
Plan-Apochromat 10x/0.45
W N-Achroplan 20x/0.5 Water
Plan-Apochromat 20x/0.8
EC Plan-Neofluar 40x/0.75
IR-Achroplan 40x/0.80 Water
Plan-Apochromat 63x/1.4 Oil DIC
Detectors: Classical PMT (range 415-735 nm)
Range detector 418-726nm
2 NND +2 BIG Detectors (LP538->LP490 SP485->BP665-610)
Filters: Visible track: MBS 458, 458/514, 458/561, 488, 488/561, 488/561/633, MBS T80/R20
Invisible track: MBS -405, -445, 690+,760+, -405/760+, -445/760+, T80/R20
Extra filters NDD: LP510, LP580, Mirror/BP500-550, LP555/BP565-610
Extra filters BIG: BP525-560/BP650-705
Room Location: W285

 


Zeiss LSM 780

Name: ZeissLSM780
Application: High resolution confocal imaging; two-photon excitation for deep tissue imaging; live cell imaging; FLIM and FRET/FLIM; spectral unmixing
Type: Invert confocal
Light Source: Diode lasers: 405, 561, 633
Argon laser: 458, 488, 514
MaiTai DeepSee multiphoton laser: range 680 – 1040 nm
Objectives: Plan-Apochromat 10x/0.45
Plan-Apochromat 20x/0.8
iLCI Plan-NeoFluar 25x/0.8 Imm Korr DIC
Plan-Apochromat 40x/1.4 Oil DIC
Plan-Apochromat 63x/1.4 Oil DIC
iLCI Plan-NeoFluar 63x/1.3 Imm Korr DIC
Detectors: Classical PMT (range 415-735 nm)
QUASAR 32-channel GaAsP detector (range 412-692 nm)
Cooled PMT (range 415-735 nm)
Filters: Visible track: MBS 458, 458/514, 458/561, 488, 488/561, 488/633, 488/561/633, MBS T80/R20
Invisible track: MBS -405, 445, 690+, -405/760+, -445/760+, T80/R20
Room Location: W280

 


Zeiss LSM880 FastAiryScan

Name: Zeiss LSM880 Fast Airy
Application: Super-resolution confocal imaging (dXY: 140 nm and dZ: 400 nm); fast and sensitive confocal imaging; regular confocal imaging; live cell imaging
Type: Invert confocal
Light Source: Diode lasers: 405, 561, 633
Argon laser: 458, 488, 514
Objectives: Plan-Apochromat 10X/0.45
iLCI Plan-Neofluar 25X/0.8 imm Korr DIC
Plan-Apochromat 40X/1.4 oil DIC
Plan-Apochromat 63X/1.4 oil
LCI Plan-Neofluar 63X/1.3 imm Korr DIC
alpha Plan-Apochromat 100X/1.46 oil DIC
Detectors: Classical PMT (range 415-735 nm)
Cooled PMT (range 415-735 nm)
Filters: Main Beam Splitters: MBS 458, 458/514, 458/561, 488, 488/561, 488/561/633, T80/R20, -405, -445
Secondary Beam Splitters: SBS BP 420-460 + LP 500, LP 525, LP 570, LP 660, LP 460, SP 615
Airy Beam Splitters: BP 420-480 + BP 495-550, BP 555-620 + LP 645, BP 420-480 + LP 605, BP 465-505 + LP 525, BP 495-550 + LP 570, BP 570-620 + LP 645
Room Location: W284

 

 

Request for project intake

For intakes of all LM projects, please contact Eef.Parthoens@irc.vib-ugent.be
[an error occurred while processing the directive]
[an error occurred while processing the directive]
[an error occurred while processing the directive]